USAfixTM - Repair Guide (RG) - Master Email RG
- Replace Vacuum Motor
 Level of Difficulty - MEDIUM  Estimated Completion Time - 45 minutes
TASKI - SWINGO 750B

Tools Required
Tool 
Screwdriver-flat tip
Screwdriver-phillips
Torx T25
Torx T30

Parts Required
PartDescriptionPriceAvailablePurchase
192-0770 24V 2 stage vacuum motor $257.63 Back Order Qty:


Step Procedure & Parts & Tools
1 TURN KEY TO TURN OFF POWER TO VAC MOTOR

2 RAISE COVER ON MACHINE TO LOCATE THE VAC MOTOR

3 USE THE PROP BAR TO PROP COVER OPEN

4 PULL DOWN ON THE FLOAT TO REMOVE IT

5 REMOVE THE 3 SCREWS HOLDING THE FILTER SCREEN TO THE COVER
Torx T30

6 PULL TO REMOVE THE FILTER SCREEN FROM THE COVER

7 SECURE THE COVER IN AN OPEN POSITION. REMOVE THE SCREW HOLDING THE PROP BAR. REMOVE THE PROP BAR FROM THE MACHINE.
Torx T30

8 PULL DOWN ON THE INSIDE COVER

9 LAY THE INSIDE COVER DOWN AND THE VAC MOTOR IS NOW VISIBLE. REMOVE 3 SCREWS HOLDING THE COLLAR TO THE VAC MOTOR.
Torx T25

10 PULL UP ON THE COLLAR TO REMOVE IT AND THE VAC MOTOR FROM THE MACHINE

11 LOOSEN THE 2 SCREWS HOLDING THE BLACK AND RED WIRES TO THE WHITE CONNECTOR. PULL GENTLY ON THE WIRES TO FREE THEM FROM THE WHITE CONNECTOR.
Screwdriver-flat tip

12 LOOSEN THE 2 SCREWS HOLDING THE 2 BLUE WIRES TO THE WHITE CONNECTOR. PULL GENTLY ON THE WIRES TO FREE THEM FROM THE WHITE CONNECTOR.
Screwdriver-flat tip

13 PULL UP ON THE RUBBER GUARD TO REMOVE IT FROM THE VAC MOTOR

14 REMOVE THE SCREW HOLDING THE WHITE CAPACITOR IN PLACE. (NOT ALL MODELS HAVE A CAPACITOR)
Screwdriver-phillips

15 PULL THE 2 WIRE CONNECTORS TO DISCONNECT THE CAPACITOR. SET CAPACITOR ASIDE.

16 LIFT UP ON THE COLLAR TO REMOVE IT FROM THE VAC MOTOR. PULL TO REMOVE THE GASKET FROM THE VAC MOTOR.

17 REVERSE STEPS 1 THRU 16 TO INSTALL A NEW VAC MOTOR AND VAC MOTOR GASKET.

PartDescriptionPriceQty
192-0770 24V 2 stage vacuum motor $257.63 Qty: